L2TestStartLinkFaultSignallingCommand Object


Description:

Starts LinkFault signaling on an Ethernet 10Gig fiber port.

Can be used with Command Sequencer: Yes

GUI Command Name: L2Test: Start Link Fault Signalling

Parents: Sequencer, StcSystem

L2TestStartLinkFaultSignallingCommand Writable Attributes

Attribute Description
Common Writable Attributes ProgressCancelled
FaultDuration

Fault duration (ms) in case of timed fault.

Type: u32

Default: 0

FaultMode

Fault mode.

Type: enum

Default: LOCAL

Possible Values:

Value Description
RESET

Stop forcing a local or remote fault. Reset will remove all forced faults from the Tx data path.

LOCAL

Local fault.

REMOTE

Remote fault.

FaultType

Type of fault to be generated.

Type: enum

Default: CONTINUOUS

Possible Values:

Value Description
CONTINUOUS

Continuous fault. Requires manual stop.

TIMED

Timed fault. Occurs for specified duration.

Port

List of port handles.

Type: handle

Default: 0

L2TestStartLinkFaultSignallingCommand Read-Only Attributes

Read-Only Attribute Description