LabelBindingGlobalConfig Object


Description:

Global system configuration for MPLS traffic label binding.

Automatically created from: Project

LabelBindingGlobalConfig Writable Attributes

Attribute Description
Common Writable Attributes Active, Name
EnableStaticPwAttachmentGroupId

Enable static PW attachment group ID.

Type: bool

Default: FALSE

Possible Values:

Value Description
TRUE

Enable static PW attachment group ID.

FALSE

Disable static PW attachment group ID.

EnableTransmitUnresolvedStream

Enable Transmit Unresolved Streams.

Type: bool

Default: TRUE

Possible Values:

Value Description
TRUE

Enable Transmit Unresolved Streams.

FALSE

Disable Transmit Unresolved Streams.

LabelResolutionMode

MPLS label resolution mode.

Type: enum

Default: PER_SESSION_LABEL_RESOLUTION

Possible Values:

Value Description
PER_SESSION_LABEL_RESOLUTION

Label storage is done in per protocol session base for the same protocol.

PER_PORT_LABEL_RESOLUTION

Label storage is done in per port base for the same protocol.

SelectDeactivedTunnelForData

MPLS traffic binding auto selection mode.

Type: bool

Default: TRUE

Possible Values:

Value Description
TRUE

Deactivated tunnels are included as part of auto selection.

FALSE

Only active tunnel are included as part of auto selection.

SubscriptionInterval

Update interval from the chassis to the Spirent TestCenter application for the label resolution summary update.

Type: u16

Default: 5

Range: 1 - 3600

LabelBindingGlobalConfig Read-Only Attributes