Description:
Link OAM event notification configuration.
Automatically created from: LinkOamRouterConfig
Attribute | Description |
---|---|
Common Writable Attributes | Active, Name |
DataValue |
Specifies the data value. Type: string Default: 00 |
ErroredFramePeriodThreshold |
Specifies the number of errored frames required to generate the event. Type: u32 Default: 1 Range: 0 - 65535 |
ErroredFramePeriodWindowSize |
Specifies the duration of the period in terms of frames. Type: u32 Default: 10 Range: 1 - 65535 |
ErroredFrameSecondsSummaryThreshold |
Specifies the number of errored frame seconds required to generate the event. Type: u16 Default: 1 Range: 0 - 65535 |
ErroredFrameSecondsSummaryWindowSize |
Specifies the period in 100 ms intervals. Type: u16 Default: 600 Range: 100 - 9000 |
ErroredFrameThreshold |
Specifies the number of errored frames required to generate the event. Type: u32 Default: 1 Range: 0 - 65535 |
ErroredFrameWindowSize |
Specifies the period in 100 ms intervals. Type: u16 Default: 10 Range: 10 - 600 |
ErroredSymbolPeriodThreshold |
Specifies the number of errored symbols required to generate the event. Type: u64 Default: 1 Range: 0 - 65535 |
ErroredSymbolPeriodWindowSize |
Specifies the number of symbols in the period. Type: u64 Default: 10 Range: 1 - 65535 |
FrameErrors |
Specifies the number of detected errored frames in the period. Type: u32 Default: 1 |
FramePeriodErrors |
Specifies the number of detected frame errors in the period. Type: u32 Default: 1 |
FrameSecondsSummaryErrors |
Specifies the number of detected errored frame seconds in the period. Type: u16 Default: 1 |
InitialTimeBase |
Specifies the initial time base in 100 ms intervals. Type: u16 Default: 0 |
MsgRepeatCount |
Specifies the number of times to transmit an event. Type: u8 Default: 2 Range: 1 - 10 |
Oui |
Specifies the OUI. Type: string Default: 00-10-94 |
SymbolPeriodErrors |
Specifies the number of detected symbol errors in the period. Type: u64 Default: 1 |