Description:
Configuration options for the custom throughput test.
Parents: Project
Attribute | Description | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Common Writable Attributes | Active, Name | ||||||||||||||
AcceptableFrameLoss |
Maximum number of frames that can be lost during an iteration in order for the iteration to be considered successful. Type: double Default: 0 Range: 0.0 - 100.0 |
||||||||||||||
Backoff |
Rate at which the load decreases after the DUT fails at the current load. Applicable when LoadType is BINARY or COMBO. Type: double Default: 50 Range: 0.001 - 99.999 |
||||||||||||||
CustomFrameSizeList |
List of frame sizes in the format of a comma-delimited string. Applicable when FrameSizeType is CUSTOM. Type: u16 Default: 0 |
||||||||||||||
DelayAfterTransmission |
Length of time you want to wait, after the test is complete, for all traffic to be received. Type: u16 Default: 15 Range: 0 - 3600 |
||||||||||||||
DurationBursts |
Transmission length in number of frames. Type: u32 Default: 1000 Range: 1 - 16777215 |
||||||||||||||
DurationMode |
Duration mode for each transmitted stream. Whether to measure test duration in seconds or number of frames. Type: enum Default: SECONDS Possible Values:
|
||||||||||||||
DurationSeconds |
Transmission time in seconds. Type: double Default: 10 Range: 0.000064 - 4398046.0 |
||||||||||||||
EnableArp |
Whether to enable or disable ARP. Enabling will append ARPing commands into the sequencer. Type: bool Default: FALSE Possible Values:
|
||||||||||||||
EnableDhcp |
Whether to enable or disable DHCP. Enabling will append DHCP related commands into the sequencer. Type: bool Default: FALSE Possible Values:
|
||||||||||||||
EnableL2Learning |
Whether to enable Layer 2 learning mode. Type: bool Default: FALSE Possible Values:
|
||||||||||||||
EnableL2tp |
Flag to add L2TP commands. Type: bool Default: FALSE Possible Values:
|
||||||||||||||
EnableOOSasFrameLoss |
Whether to enable or disable out of sequence frame as frame loss in the test. Type: bool Default: FALSE Possible Values:
|
||||||||||||||
EnablePauseBeforeTraffic |
If this option is enabled, this will pause the sequencer prior to starting traffic. This pause allows you time to do a final DUT check (for example, check routes) before Spirent TestCenter proceeds with traffic start. Type: bool Default: FALSE Possible Values:
|
||||||||||||||
EnablePpp |
Whether to enable or disable PPP. Enabling will append PPP related commands into the sequencer. Type: bool Default: FALSE Possible Values:
|
||||||||||||||
EnableRouter |
Whether to enable or disable router. Enabling will append commands to start and stop all routers into the sequencer. Type: bool Default: FALSE Possible Values:
|
||||||||||||||
EnableSavePortPairLatencyResults |
Enable Save Port Pair Latency Results in custom throughput test. Type: bool Default: FALSE Possible Values:
|
||||||||||||||
EnableWaitAfterAdvertisement |
Whether to wait until advertisement completes. Enabling will append commands into the sequencer to wait for routing events and states. Type: bool Default: TRUE Possible Values:
|
||||||||||||||
EnableWaitForMplsBinding |
Flag to indicate whether to wait for MPLS binding. If enabled, traffic waits for MPLS streams to bind. Type: bool Default: FALSE Possible Values:
|
||||||||||||||
FixedInterburstGapValue |
Constant inter-burst gap value for all iterations. This attribute is ignored when InterBurstGapMode is RANDOM. Type: u8 Default: 0 Range: 0 - 100 |
||||||||||||||
FrameSizeEnd |
Maximum frame size when using Step mode for incrementing the frame size. This attribute is ignored if FrameSizeType is set to RANDOM, FIXED or CUSTOM. Type: u16 Default: 256 Range: 40 - 16383 |
||||||||||||||
FrameSizeStart |
Starting frame size when using Step mode for incrementing the frame size. This attribute is ignored if FrameSizeType is set to RANDOM, FIXED or CUSTOM. Type: u16 Default: 128 Range: 40 - 16383 |
||||||||||||||
FrameSizeStep |
Step value for incrementing the frame size from StartFrameSize to StopFrameSize. This attribute is ignored if FrameSizeType is set to RANDOM, FIXED or CUSTOM. Type: u16 Default: 128 Range: 1 - 16383 |
||||||||||||||
FrameSizeType |
Method of setting the frame size. Type: enum Default: STEP Possible Values:
|
||||||||||||||
IgnoreMinMaxLimits |
Specifies whether the search stops at the specified RateLowerLimit or RateUpperLimit value, or whether it continues beyond those limits if an acceptable load has not yet been found. Only applicable when LoadType is STEP. Type: bool Default: FALSE Possible Values:
|
||||||||||||||
ImixDistributionList |
Specifies the selected iMIX distribution to be used from the available iMIX distributions in Spirent TestCenter. Type: handle Default: 0 |
||||||||||||||
InterburstGapMode |
Specifies the inter-burst gap mode, the idle time between packets, as either fixed or random. Type: enum Default: FIXED Possible Values:
|
||||||||||||||
LatencyDistributionList |
List of up to 16 time intervals (latency buckets) into which received-frame latency values will be directed. Type: u16 Default: 2 |
||||||||||||||
LoadType |
Method of setting the load rate. Type: enum Default: BINARY Possible Values:
|
||||||||||||||
LoadUnits |
Unit of measurement for the load parameter, applied to all ports and streams in the test. Type: enum Default: PERCENT_LINE_RATE Possible Values:
|
||||||||||||||
PerformL2Learning |
Specifies when to perform Layer 2 learning. Type: enum Default: BEFORE_TEST Possible Values:
|
||||||||||||||
RandomMaxFrameSize |
Maximum frame size when FrameSizeType is RANDOM. This attribute is ignored if FrameSizeType is set to STEP, FIXED or CUSTOM. Type: u16 Default: 256 Range: 40 - 16383 |
||||||||||||||
RandomMaxInterburstGapValue |
Maximum inter-burst gap value for all iterations. This attribute is ignored when InterBurstGapMode is FIXED. Type: u8 Default: 12 Range: 0 - 100 |
||||||||||||||
RandomMinFrameSize |
Minimum frame size when FrameSizeType is RANDOM. This attribute is ignored if FrameSizeType is set to STEP, FIXED or CUSTOM. Type: u16 Default: 128 Range: 40 - 16383 |
||||||||||||||
RandomMinInterburstGapValue |
Minimum inter-burst gap value for all iterations. This attribute is ignored when InterBurstGapMode is FIXED. Type: u8 Default: 12 Range: 0 - 100 |
||||||||||||||
RateInitial |
If LoadType is set to BINARY, the load rate at the beginning of the test. This attribute is ignored if LoadType is set to STEP. Type: double Default: 10 |
||||||||||||||
RateLowerLimit |
If LoadType is set to STEP, the starting throughput rate for each port. This attribute is ignored if LoadType is set to BINARY. Type: double Default: 10.0 |
||||||||||||||
RateStep |
Amount the throughput increases from iteration to iteration. This attribute is ignored if LoadType is set to BINARY. Type: double Default: 1 Range: 0.001 - 100000000000.0 |
||||||||||||||
RateUpperLimit |
If LoadType is set to STEP, the maximum throughput rate for each port. This attribute is ignored if LoadType is set to BINARY. Type: double Default: 100 |
||||||||||||||
Resolution |
Finest adjustment possible for the load from iteration to iteration. If the required adjustment to the current load for the next iteration is less than the resolution, the search stops. Applicable when LoadType is BINARY or COMBO. Type: double Default: 1.0 Range: 0.001 - 1000.0 |
||||||||||||||
ResultsOption |
Results Option for the test Type: enum Default: CLASSIC Possible Values:
|
||||||||||||||
StartTrafficDelay |
This is the number of seconds to wait before sending traffic. This setting gives you the flexibility to start traffic a specific number of seconds after test start, or after advertisement is complete. Type: u16 Default: 2 Range: 0 - 3600 |
||||||||||||||
TrafficStartMode |
Traffic start mode to use. Type: enum Default: SYNCHRONOUS Possible Values:
|
Read-Only Attribute | Description |
---|---|
TestType |
Test type is Custom. Type: string Default: Custom |