Description:
Defines the characteristics of an emulated TWAMP test session. This is the TWAMP test session configuration object.
Parents: TwampClientConfig
Result children (automatically created): TwampTestSessionResults
Relations:
Side name (Type) |
Relative | Description |
---|---|---|
ResultChild (ResultChild) |
Use this to connect a results object to an object. |
Attribute | Description | ||||||||
---|---|---|---|---|---|---|---|---|---|
Common Writable Attributes | Active, Name | ||||||||
DSCP |
Diffserv code point. Type: u8 Default: 0 Range: 0 - 63 |
||||||||
DstUdpPort |
NOTE: This attribute is deprecated. It will be removed in subsequent releases, so it is recommended that you do not use it. Destination UDP port. Type: u16 Default: 123 Range: 1 - 65535 |
||||||||
Duration |
Duration Type: u32 Default: 60 |
||||||||
DurationMode |
Duration mode. Type: enum Default: SECONDS Possible Values:
|
||||||||
FrameRate |
Frame rate (f/sec). Type: u32 Default: 10 Range: 1 - 1000 |
||||||||
PacketCount |
Packet count. Type: u32 Default: 100 |
||||||||
PaddingLength |
Padding length. Type: u16 Default: 128 Range: 27 - 9000 |
||||||||
PaddingPattern |
Padding pattern. Type: enum Default: RANDOM Possible Values:
|
||||||||
PaddingUserDefinedPattern |
User-defined padding pattern. Type: string Default: spirent |
||||||||
PaddingUserDefinedPatternHex |
User-defined padding pattern to be Hex. Type: u8 Default: 0 |
||||||||
ScalabilityMode |
Scalability mode, enable or disable test session result collection. Type: enum Default: NORMAL Possible Values:
|
||||||||
SessionDstUdpPort |
Destination UDP port. Type: u16 Default: 5450 Range: 1 - 65535 |
||||||||
SessionSrcUdpPort |
Source UDP port. Type: u16 Default: 5450 Range: 1 - 65535 |
||||||||
SrcUdpPort |
NOTE: This attribute is deprecated. It will be removed in subsequent releases, so it is recommended that you do not use it. Source UDP port. Type: u16 Default: 123 Range: 1 - 65535 |
||||||||
StartDelay |
Start delay (sec). Type: u32 Default: 5 |
||||||||
Timeout |
Timeout (sec). Type: u32 Default: 30 |
||||||||
Ttl |
Time to live. Type: u8 Default: 255 Range: 1 - 255 |
Read-Only Attribute | Description | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SessionState |
State of the TWAMP test session. Type: enum Default: IDLE Possible Values:
|