eCPRI Message Parameters

Multiple eCPRI messages can be configured in the Configure eCPRI Messages dialog box for each eCPRI device block.

Each row in the grid represents one message type. The tables below define the parameters used to configure messages.

Additional commands are available via the toolbar and shortcut menu.

eCPRI Control and User Data . eCPRI Remote Memory Access . eCPRI Delay Measurement . eCPRI Remote Reset . eCPRI Event Indication

Common Fields

Toolbar Buttons

Button Description
Add Add a message
Delete Delete the selected messages

Grid

Field Description Values Default

Port Name

Read-only port name N/A N/A
Device Name Read-onlydevice name N/A N/A
eCPRI Message Default name used to identify this message 255 alphanumeric characters Assigned system name
Active

Select to enable the message.

Clear to disable the message. Disabled messages are not used in a test.

The configuration for a message is retained when it is disabled and is available as configured if the message is re-enabled.

N/A Selected
Reserved Value of the reserved bits 0-7 0

eCPRI Control and User Data

Toolbar Buttons

Button Description
Send Remote Memory Access Message Send one RMA message on the selected rows
Update eCPRI Streams Update the streams on the selected rows
Send Control and User Data Messages at PTP time Send eCPRI control and user data streams on the selected rows at the PTP time specified in the Cycle Time field on the eCPRI port tab

Grid

Field Description Values Default
eCPRI Message Type Type of eCPRI message eCPRI IQ Data (Type-0), BIT Sequence (Type-1), Generic Data Transfer (Type-3), Custom (Vendor Specific) Message eCPRI IQ Data (Type-0)
Custom Message Type

Available when eCPRI Message Type is set to Custom (Vendor Specific) Message

Type identifier for the custom message

64-255 64
Number of PCs per Device Number of physical channels to emulate for each device 1-65535 1
Message Allocation Type Method of allocating messages Fixed, Random Fixed
Number of Messages per Physical Channel

Available when Message Allocation Type is set to Random

Number of messages to send for each emulated physical channel

1-65535 1
Message Count Min Value

Available when Message Allocation Type is set to Random

Lower end of the range of the random number of messages

1-65535 0
Message Count Max Value

Available when Message Allocation Type is set to Random

Upper end of the range of the random number of messages

1-65535 100
Set Control Info Select to configure control info N/A Cleared
Control Info (Hex)

Available when Set Control Info is selected

Click the ellipsis to edit the real-time control pertaining to the user data

Valid hexadecimal value 00
Send Control Info First

Available when Set Control Info is selected

Select to send the control info at the beginning of the message

Clear to send the control info at the end of the message

N/A Selected
User Data (Hex) Click the ellipsis to edit the user data field Valid hexadecimal value 00
PC ID Value of the first physical channel ID 0-65535 0
PC ID Step Increment value with which to create subsequent IDs 0-65535 0
Seq ID Value of the first message ID 0-65535 0
Seq ID Step Increment value with which to create subsequent IDs 0-65535 0
Concatenation Select to include multiple eCPRI messages in the eCPRI PDU N/A Cleared
Load (frames/sec) Number of frames per second to send 1-4294967295 1
Frame Size Size of frame in bytes 18-16383 128

eCPRI Remote Memory Access

Toolbar Buttons

Button Description
Send Remote Memory Access Message Send one RMI message on the selected rows

Grid

Field Description Values Default
Access Type Type of access Read, Write, Write No Response Read
Action Type Type of action to configure Request Request
Access ID Unique identifier for the action 1-255 1
Element ID

Implementation-dependent instance identifier of a hardware function

1-65535 1
Concatenation Select to include multiple eCPRI messages in the eCPRI PDU N/A Cleared
Address Memory location of the data to be read or written 0-281474976710655 0
DataLength Size of data field in bytes 18-16383 128
Data (Hex)

Available when Access Type is set to Write or Write No Response

Click the ellipsis to edit the user data field

Valid hexadecimal value 00

eCPRI Delay Measurement

Toolbar Buttons

Button Description
Send Delay Measurement Message Send one DM message on the selected rows

Grid

Field Description Values Default
Action Type Type of action to configure

Request, Request with Followup, Remote Request, Remote Request with Followup

Request
Number of Messages Read-only number of messages to be sent N/A 1
Measurement ID Unique identifier for Reqeust with Followup messages 1-255 1
Concatenation Select to include multiple eCPRI messages in the eCPRI PDU N/A Cleared
Time Compensation Value (nano sec) The time stamp collected at the PHY in nanoseconds N/A 0
Response Timeout Value (micro sec) Number of microseconds to wait for a response before timing out 0-4294967295 0
Dummy Data (Hex) Click the ellipsis to edit the data field Valid hexadecimal value 01

eCPRI Remote Reset

Toolbar Buttons

Button Description
Send Remote Reset Message Send one RR message on the selected rows

Grid

Field Description Values Default
Reset ID Vendor specific ID 0-65535 0
Reset Code Op Op code Remote Reset Request (0x01) Remote Reset Request
Vendor Specific Payload (Hex) Click the ellipsis to edit the data field Valid hexadecimal value Null
Concatenation Select to include multiple eCPRI messages in the eCPRI PDU N/A Cleared

eCPRI Event Indication

Toolbar Buttons

Button Description
Add Event Indication Add an event indication message
Add Fault/Notification Info Add a fault/notification message under the event indication message
Send Event Indication Message Send one EI message on the selected rows

Grid

Field Description Values Default
Event ID 1-byte identifier for messages between peers 0-255 1
Event Type Type of event notification message Fault(s) Indication, Fault(s) Indication Ack, Notification Indication, Sync Request, Sync Ack, Sync End Indication Fault(s) Indication
Sequencer Number 1-byte value that is incremented each time the transmitter sends an event indication with a type of Fault(s) Indication 1-255 0
Fault notification info
Name Default name used to identify this fault notification 255 alphanumeric characters Assigned system name
Element ID Identifier for the notification node 0-65535 0
Action Indicates whether to raise or cease a notification Raise, Cease Raise
Fault/Notification Number Types of faults and notifications General User Plane HW Fault, General User Plane SW fault, Unknown message type received, Unknown data buffer underflow, Unknown data buffer overflow, Userplane data arrived too early General User Plane HW Fault
Additional Info (hex) 4-byte user configurable data value 00000000-FFFFFFFF 0

eCPRI Device Parameters