Ieee1588v2PortConfig Object


Description:

Ieee1588v2 port configuaration

Automatically created from: Port

Ieee1588v2PortConfig Writable Attributes

Attribute Description
Common Writable Attributes Active, Name
BeforeAndAfterThresholdRowCount

Number of previous and next rows to be captured in results when current offset is lower than Lower Offset and greater than Upper Offset threshold value

Type: u8

Default: 0

Range: 0 - 10

EnableClockSyncFilteredResult

STC populates clock sync filtered results only if this flag is enabled, along with this user must select same in results selector under TestCenter IQ Settings

Type: bool

Default: FALSE

Possible Values:

Value Description
TRUE

Collects the Clock sync filtered results.

FALSE

Disables the Collection of Clock sync filtered results.

LowerOffsetThreshold

Lower bound on offset value in nano seconds, clock sync results shall be captured only when Current offset is lower than Lower offset threshold

Type: s64

Default: -300

MeasureSeqIdErrors

STC measures invalid or not recieved packet count based on sequnce ids only if this field id enabled and publish in results

Type: bool

Default: FALSE

Possible Values:

Value Description
TRUE

Sequnce ID errors shall be measured.

FALSE

Sequnce ID errors shall not be measured.

RxLogSyncInterval

Received Sync packets interval in terms of logarithmic base 2 values

Type: s8

Default: 0

Range: -128 - 127

UpperOffsetThreshold

Upper bound on offset value in nano seconds, clock sync results shall be captured only when Current offset is greater than Upper offset threshold

Type: s64

Default: 300

Ieee1588v2PortConfig Read-Only Attributes