Description:
Ieee1588v2 port configuaration
Automatically created from: Port
Attribute | Description | ||||||
---|---|---|---|---|---|---|---|
Common Writable Attributes | Active, Name | ||||||
BeforeAndAfterThresholdRowCount |
Number of previous and next rows to be captured in results when current offset is lower than Lower Offset and greater than Upper Offset threshold value Type: u8 Default: 0 Range: 0 - 10 |
||||||
EnableClockSyncFilteredResult |
STC populates clock sync filtered results only if this flag is enabled, along with this user must select same in results selector under TestCenter IQ Settings Type: bool Default: FALSE Possible Values:
|
||||||
LowerOffsetThreshold |
Lower bound on offset value in nano seconds, clock sync results shall be captured only when Current offset is lower than Lower offset threshold Type: s64 Default: -300 |
||||||
MeasureSeqIdErrors |
STC measures invalid or not recieved packet count based on sequnce ids only if this field id enabled and publish in results Type: bool Default: FALSE Possible Values:
|
||||||
RxLogSyncInterval |
Received Sync packets interval in terms of logarithmic base 2 values Type: s8 Default: 0 Range: -128 - 127 |
||||||
UpperOffsetThreshold |
Upper bound on offset value in nano seconds, clock sync results shall be captured only when Current offset is greater than Upper offset threshold Type: s64 Default: 300 |
There are no read-only attributes.