PfcMeasurementConfig Object


Description:

PFC measurement configuration.

Parents: Port

Relations:

Side name
(Type)
Relative Description
SamplingConfig
(AffiliatedPfcTrigger)

HighResolutionSamplingPortConfig, HighResolutionSamplingStreamBlockConfig

Relation to link PfcConfig to HighResSamplingConfig

PfcMeasurementConfig Writable Attributes

Attribute Description
Common Writable Attributes Active, Name
AutoTrigger

Use auto trigger

Type: bool

Default: FALSE

Possible Values:

Value Description
TRUE

Rate based PFC measurement will be used

FALSE

Rate based PFC measurement will not be used

EnableXon

Enable XON delay.

Type: bool

Default: FALSE

Possible Values:

Value Description
TRUE

Enable XON delay.

FALSE

Enable XON delay.

OptimizedXon

NOTE: This attribute is deprecated. It will be removed in subsequent releases, so it is recommended that you do not use it.

Determines how an emulated device responds to an Xon sent by a DUT

Type: enum

Default: DISABLE

Possible Values:

Value Description
DISABLE

The emulated device does not restart transmission as soon as it receives an XON from the DUT

ENABLE

The emulated device restarts transmission as soon as it receives an XON from the DUT

PriorityEnable

Enable VLAN priority, start from P0 to P7.

Type: bool

Default: FALSE

Possible Values:

Value Description
TRUE

Priority is enabled.

FALSE

Priority is disabled.

Time

Request pause time.

Type: u16

Default: 0

XonDelay

XON delay time.

Type: double

Default: 1.0

Range: 1 - 3273000

XonDelayUnit

XON delay time unit.

Type: enum

Default: PAUSE_QUANTA

Possible Values:

Value Description
PAUSE_QUANTA

Use quanta as the unit.

MICROSECONDS

Use microseconds as the unit.

PfcMeasurementConfig Read-Only Attributes