Description:
Returns the SONET interface section/line alarms and the SONET interface path alarms.
Parents: Port
Relations:
Side name (Type) |
Relative | Description |
---|---|---|
ResultParent (ResultChild) |
Use this to connect a results object to an object. |
There are no writable attributes.
Read-Only Attribute | Description |
---|---|
Aisl |
Returns the status of the line AIS alarm. Returns the status of the section Out of Frame (OOF) alarm. 0 - The alarm has not been detected. 1 - The alarm is currently detected. 2 - The alarm was detected at some time. Type: u8 Default: 0 |
Aisp |
Returns the status of the path AIS alarm. 0 - The alarm has not been detected. 1 - The alarm is currently detected. 2 - The alarm was detected at some time. Type: u8 Default: 0 |
AlarmsBasicTimestamp |
Deprecated, do not use. Type: string Default: 0 |
C2 |
Returns the C2 overhead byte. Type: u8 Default: 0 |
J0 |
Returns the J0 trace values in the specified format. Type: string Default: 0 |
J0unst |
Returns the status of the J0 unstable alarm. 0 - The alarm has not been detected. 1 - The alarm is currently detected. 2 - The alarm was detected at some time. Type: u8 Default: 0 |
J1 |
Returns the J1 trace values in the specified format. Type: string Default: 0 |
J1unst |
Returns the status of the J1 unstable alarm. 0 - The alarm has not been detected. 1 - The alarm is currently detected. 2 - The alarm was detected at some time. Type: u8 Default: 0 |
K1 |
Returns the K1 overhead byte. Type: u8 Default: 0 |
K2 |
Returns the K2 overhead byte. Type: u8 Default: 0 |
Kchg |
Returns the status of the K1/K2 changed alarm. 0 - The alarm has not been detected. 1 - The alarm is currently detected. 2 - The alarm was detected at some time. Type: u8 Default: 0 |
Kunst |
Returns the status of the K1/K2 unstable alarm. 0 - The alarm has not been detected. 1 - The alarm is currently detected. 2 - The alarm was detected at some time. Type: u8 Default: 0 |
LastModified |
Deprecated, do not use. Type: string Default: 0 |
Lof |
Returns the status of the section LOF alarm. Returns the status of the section Out of Frame (OOF) alarm. 0 - The alarm has not been detected. 1 - The alarm is currently detected. 2 - The alarm was detected at some time. Type: u8 Default: 0 |
Lopp |
Returns the status of the path LOP alarm. A LOP alarm is triggered when invalid pointers are found in 8 consecutive frames or if 8 consecutive new data flags (NDF) are received. 0 - The alarm has not been detected. 1 - The alarm is currently detected. 2 - The alarm was detected at some time. Type: u8 Default: 0 |
Los |
Returns the status of the section LOS alarm. 0 - The alarm has not been detected. 1 - The alarm is currently detected. 2 - The alarm was detected at some time. Type: u8 Default: 0 |
Oocd |
ATM Out-Of-Cell-Delineation. Type: u8 Default: 0 |
Oof |
Returns the status of the section Out of Frame (OOF) alarm. 0 - The alarm has not been detected. 1 - The alarm is currently detected. 2 - The alarm was detected at some time. Type: u8 Default: 0 |
Plmp |
Returns the status of the path PLM alarm. A PLM alarm is triggered when the observed C2 signal label value does not match the expected signal label value. 0 - The alarm has not been detected. 1 - The alarm is currently detected. 2 - The alarm was detected at some time. Type: u8 Default: 0 |
Rdil |
Returns the status of the line RDI alarm. Returns the status of the section Out of Frame (OOF) alarm. 0 - The alarm has not been detected. 1 - The alarm is currently detected. 2 - The alarm was detected at some time. Type: u8 Default: 0 |
Rdip |
Returns the status of the path RDI alarm. A path RDI alarm is triggered upon detecting a loss of signal, loss of frame, or AIS defect. 0 - The alarm has not been detected. 1 - The alarm is currently detected. 2 - The alarm was detected at some time. Type: u8 Default: 0 |
S1 |
Returns the S1 overhead byte. Type: u8 Default: 0 |
Timp |
Returns the status of the path TIM alarm. 0 - The alarm has not been detected. 1 - The alarm is currently detected. 2 - The alarm was detected at some time. Type: u8 Default: 0 |
Uneqp |
Returns the status of the path Unequipped alarm. A path Unequipped alarm is triggered when C2 signal label value is 0x00. 0 - The alarm has not been detected. 1 - The alarm is currently detected. 2 - The alarm was detected at some time. Type: u8 Default: 0 |