SonetAlarmsResults Object


Description:

Returns the SONET interface section/line alarms and the SONET interface path alarms.

Parents: Port

Relations:

Side name
(Type)
Relative Description
ResultParent
(ResultChild)

Port

Use this to connect a results object to an object.

SonetAlarmsResults Writable Attributes

There are no writable attributes.

SonetAlarmsResults Read-Only Attributes

Read-Only Attribute Description
Aisl

Returns the status of the line AIS alarm.

Returns the status of the section Out of Frame (OOF) alarm.

0 - The alarm has not been detected.

1 - The alarm is currently detected.

2 - The alarm was detected at some time.

Type: u8

Default: 0

Aisp

Returns the status of the path AIS alarm.

0 - The alarm has not been detected.

1 - The alarm is currently detected.

2 - The alarm was detected at some time.

Type: u8

Default: 0

AlarmsBasicTimestamp

Deprecated, do not use.

Type: string

Default: 0

C2

Returns the C2 overhead byte.

Type: u8

Default: 0

J0

Returns the J0 trace values in the specified format.

Type: string

Default: 0

J0unst

Returns the status of the J0 unstable alarm.

0 - The alarm has not been detected.

1 - The alarm is currently detected.

2 - The alarm was detected at some time.

Type: u8

Default: 0

J1

Returns the J1 trace values in the specified format.

Type: string

Default: 0

J1unst

Returns the status of the J1 unstable alarm.

0 - The alarm has not been detected.

1 - The alarm is currently detected.

2 - The alarm was detected at some time.

Type: u8

Default: 0

K1

Returns the K1 overhead byte.

Type: u8

Default: 0

K2

Returns the K2 overhead byte.

Type: u8

Default: 0

Kchg

Returns the status of the K1/K2 changed alarm.

0 - The alarm has not been detected.

1 - The alarm is currently detected.

2 - The alarm was detected at some time.

Type: u8

Default: 0

Kunst

Returns the status of the K1/K2 unstable alarm.

0 - The alarm has not been detected.

1 - The alarm is currently detected.

2 - The alarm was detected at some time.

Type: u8

Default: 0

LastModified

Deprecated, do not use.

Type: string

Default: 0

Lof

Returns the status of the section LOF alarm.

Returns the status of the section Out of Frame (OOF) alarm.

0 - The alarm has not been detected.

1 - The alarm is currently detected.

2 - The alarm was detected at some time.

Type: u8

Default: 0

Lopp

Returns the status of the path LOP alarm. A LOP alarm is triggered when invalid pointers are found in 8 consecutive frames or if 8 consecutive new data flags (NDF) are received.

0 - The alarm has not been detected.

1 - The alarm is currently detected.

2 - The alarm was detected at some time.

Type: u8

Default: 0

Los

Returns the status of the section LOS alarm.

0 - The alarm has not been detected.

1 - The alarm is currently detected.

2 - The alarm was detected at some time.

Type: u8

Default: 0

Oocd

ATM Out-Of-Cell-Delineation.

Type: u8

Default: 0

Oof

Returns the status of the section Out of Frame (OOF) alarm.

0 - The alarm has not been detected.

1 - The alarm is currently detected.

2 - The alarm was detected at some time.

Type: u8

Default: 0

Plmp

Returns the status of the path PLM alarm. A PLM alarm is triggered when the observed C2 signal label value does not match the expected signal label value.

0 - The alarm has not been detected.

1 - The alarm is currently detected.

2 - The alarm was detected at some time.

Type: u8

Default: 0

Rdil

Returns the status of the line RDI alarm.

Returns the status of the section Out of Frame (OOF) alarm.

0 - The alarm has not been detected.

1 - The alarm is currently detected.

2 - The alarm was detected at some time.

Type: u8

Default: 0

Rdip

Returns the status of the path RDI alarm. A path RDI alarm is triggered upon detecting a loss of signal, loss of frame, or AIS defect.

0 - The alarm has not been detected.

1 - The alarm is currently detected.

2 - The alarm was detected at some time.

Type: u8

Default: 0

S1

Returns the S1 overhead byte.

Type: u8

Default: 0

Timp

Returns the status of the path TIM alarm.

0 - The alarm has not been detected.

1 - The alarm is currently detected.

2 - The alarm was detected at some time.

Type: u8

Default: 0

Uneqp

Returns the status of the path Unequipped alarm. A path Unequipped alarm is triggered when C2 signal label value is 0x00.

0 - The alarm has not been detected.

1 - The alarm is currently detected.

2 - The alarm was detected at some time.

Type: u8

Default: 0