SonetInjectors Object


Description:

Controls for the continuous interface section/line error injector triggers for the interface.

Automatically created from: AtmPhy, POSPhy

SonetInjectors Writable Attributes

Attribute Description
Common Writable Attributes Active, Name

SonetInjectors Read-Only Attributes

Read-Only Attribute Description
LineAis

Triggers the injection of the Alarm Indication Signal (AIS) alarm, which inserts 0xFF into all bytes, except the section overhead.

Type: enum

Default: OFF

Possible Values:

Value Description
OFF

Disables the continuous error injection condition.

MOMENTARY

Triggers a momentary error condition. (Not currently supported).

START

Enables the continuous error injection condition.

LineB2

Triggers the injection of bit errors in the B2 byte value.

Type: enum

Default: OFF

Possible Values:

Value Description
OFF

Disables the continuous error injection condition.

MOMENTARY

Triggers a momentary error condition. (Not currently supported).

START

Enables the continuous error injection condition.

LineRdi

Triggers the injection of the Remote Defect Indication (RDI) alarm, by inserting 110 in bits 6, 7, and 8 of the K2 byte.

Type: enum

Default: OFF

Possible Values:

Value Description
OFF

Disables the continuous error injection condition.

MOMENTARY

Triggers a momentary error condition. (Not currently supported).

START

Enables the continuous error injection condition.

LineRei

Triggers the injection of the Remote Error Indication (REI) alarm, by inserting an REI count of 1 in the M1 byte.

Type: enum

Default: OFF

Possible Values:

Value Description
OFF

Disables the continuous error injection condition.

MOMENTARY

Triggers a momentary error condition. (Not currently supported).

START

Enables the continuous error injection condition.

SectionB1

Triggers the injection of bit errors in the B1 byte value.

Type: enum

Default: OFF

Possible Values:

Value Description
OFF

Disables the continuous error injection condition.

MOMENTARY

Triggers a momentary error condition. (Not currently supported).

START

Enables the continuous error injection condition.

SectionLof

A severely errored frame condition is triggered to produce a loss of frame (LOF) condition.

Type: enum

Default: OFF

Possible Values:

Value Description
OFF

Disables the continuous error injection condition.

MOMENTARY

Triggers a momentary error condition. (Not currently supported).

START

Enables the continuous error injection condition.

SectionLos

Triggers the injection of continuous zeros in the incoming data stream to trigger a loss of signal (LOS) condition.

Type: enum

Default: OFF

Possible Values:

Value Description
OFF

Disables the continuous error injection condition.

MOMENTARY

Triggers a momentary error condition. (Not currently supported).

START

Enables the continuous error injection condition.