SonetPathInjectors Object


Description:

Controls for the continuous interface path error injector triggers for the interface.

Automatically created from: AtmPhy, POSPhy

SonetPathInjectors Writable Attributes

Attribute Description
Common Writable Attributes Active, Name

SonetPathInjectors Read-Only Attributes

Read-Only Attribute Description
PathAis

Triggers the injection of a path AIS alarm, which inserts 0xFF into pointer bytes H1, H2, and H3 and Synchronous Payload Envelope bytes for a particular path.

Type: enum

Default: OFF

Possible Values:

Value Description
OFF

Disables the continuous error injection condition.

MOMENTARY

Triggers a momentary error condition. (Not currently supported).

START

Enables the continuous error injection condition.

PathB3

Triggers the injection of bit errors in the B3 byte value.

Type: enum

Default: OFF

Possible Values:

Value Description
OFF

Disables the continuous error injection condition.

MOMENTARY

Triggers a momentary error condition. (Not currently supported).

START

Enables the continuous error injection condition.

PathLop

Triggers the injection of a path Loss of Pointer (LOP) alarm. A LOP alarm is triggered when invalid pointers are found in 8 consecutive frames or if 8 consecutive new data flags (NDF) are received.

Type: enum

Default: OFF

Possible Values:

Value Description
OFF

Disables the continuous error injection condition.

MOMENTARY

Triggers a momentary error condition. (Not currently supported).

START

Enables the continuous error injection condition.

PathPlm

Triggers the injection of a path Payload Label Mismatch (PLM) alarm. A PLM alarm is triggered when the observed C2 signal label value does not match that of the expected signal label value.

Type: enum

Default: OFF

Possible Values:

Value Description
OFF

Disables the continuous error injection condition.

MOMENTARY

Triggers a momentary error condition. (Not currently supported).

START

Enables the continuous error injection condition.

PathRdi

Triggers the injection of a path RDI alarm. A path RDI alarm is triggered upon detecting a loss of signal, loss of frame, or AIS defect.

Type: enum

Default: OFF

Possible Values:

Value Description
OFF

Disables the continuous error injection condition.

MOMENTARY

Triggers a momentary error condition. (Not currently supported).

START

Enables the continuous error injection condition.

PathRei

Triggers the injection of a path REI alarm. A path REI alarm is triggered when B3 BIP-8 errors are detected at the far end device.

Type: enum

Default: OFF

Possible Values:

Value Description
OFF

Disables the continuous error injection condition.

MOMENTARY

Triggers a momentary error condition. (Not currently supported).

START

Enables the continuous error injection condition.

PathUnequipped

Triggers the injection of a path Unequipped alarm. A path Unequipped alarm is triggered when C2 signal label value is 0x00.

Type: enum

Default: OFF

Possible Values:

Value Description
OFF

Disables the continuous error injection condition.

MOMENTARY

Triggers a momentary error condition. (Not currently supported).

START

Enables the continuous error injection condition.