SonetResults Object


Description:

Returns the SONET interface section/line statistics and the SONET interface path statistics.

Parents: Port

Relations:

Side name
(Type)
Relative Description
ResultParent
(ResultChild)

Port

Use this to connect a results object to an object.

SonetResults Writable Attributes

There are no writable attributes.

SonetResults Read-Only Attributes

Read-Only Attribute Description
AbortCount

Returns a count of aborted POS packets.

Type: u64

Default: 0

AbortRate

Returns the rate in error/s of aborted POS packets.

Type: u64

Default: 0

CounterTimestamp

Deprecated, do not use.

Type: string

Default: 0

DropCount

Returns a count of dropped POS packets.

Type: u64

Default: 0

DropRate

Returns the rate in error/s of dropped POS packets.

Type: u64

Default: 0

LastModified

Deprecated, do not use.

Type: string

Default: 0

LineCount

Returns a count of B2 BIP-8 errors that have been detected.

Type: u64

Default: 0

LineRate

Returns the ratio of B2 BIP-8 errors to the number of bits in the SONET frame received during the elapsed test time.

Type: u64

Default: 0

PathCount

Returns a count of B3 BIP-8 errors that have been detected.

Type: u64

Default: 0

PathRate

Returns a count of B3 BIP-8 errors that have been detected.

Type: u64

Default: 0

RateTimestamp

Deprecated, do not use.

Type: string

Default: 0

REILCount

Returns the Remote Error Indication count, which is the count of B2 errors received the far end.

Type: u64

Default: 0

REILRate

Returns the ratio of REI errors to the number of bits in the SONET frame (except for section overhead) received during the elapsed test time.

Type: u64

Default: 0

REIPCount

Returns an REI error count, which is a count of the B3 BIP-8 detected at the far end device.

Type: u64

Default: 0

REIPRate

Returns an REI error count, which is a count of the B3 BIP-8 detected at the far end device.

Type: u64

Default: 0

SectionCount

Returns a count of B1 BIP-8 errors that have been detected.

Type: u64

Default: 0

SectionRate

Returns the ratio of B1 BIP-8 errors to the number of bits in the SONET frame received during the elapsed test time.

Type: u64

Default: 0